Climax Combined Filter A1P2 NR – Model 755 (Pair)

Regular price EGP 195
Sale price EGP 195 Regular price
Unit price
Compare Ask a question

Ask a Question

* Required fields

Size guide Share
Climax Combined Filter A1P2 NR – Model 755 (Pair)

Climax Combined Filter A1P2 NR – Model 755 (Pair)

Product description
Shipping & Return

The Climax 755 A1P2 NR Combined Filter is a dual-protection gas and particulate filter from Spain's Productos Climax, designed for use with Climax half-face respirator masks. It provides Class A1 protection against organic vapours combined with P2 NR particulate filtration — making it a versatile single filter for environments with mixed gas, vapour, and aerosol hazards. The P2 particulate layer is independently replaceable, extending the service life of the gas filter body.

Key Features

  • Combined A1 + P2 NR protection — single filter provides both organic vapour/gas and particulate protection simultaneously
  • Replaceable P2 NR particulate layer — the P2 non-woven filter element is positioned on top of the gas filter cap and secured with a retainer ring; can be replaced independently when exhausted without discarding the gas filter body
  • Multi-layer P2 non-woven filter media — engineered for maximum filtration efficiency against both solid and liquid aerosols
  • Non-standard screw thread — compatible exclusively with Climax masks models 755, 756, and 810
  • Lightweight ABS plastic body — durable and low-profile for minimal weight on the facepiece
  • Sold as a pair (2 filters per pack)

What It Protects Against

  • A1 — Organic vapours and gases with boiling point above 65°C (e.g. solvents, hydrocarbons, paint thinners)
  • P2 NR — Solid and liquid aerosols — dusts, mists, fumes, and non-volatile particles
  • Paint spray mist and solvent vapours
  • Pesticide and herbicide aerosols with organic vapour content
  • Industrial dusts and grinding/welding fumes (light exposure)

Protection Standard

Certified to EN 14387:2004 + A1:2008 — Combined gas and particulate filter, Class A1P2 NR. CE certified (0161). Colour code: Brown (A1) + White (P2) per EN classification. NR = Non-Reusable particulate layer — discard P2 element when breathing resistance increases or at end of shift.

Compatible Masks

  • Climax 755 — half-face thermoplastic rubber respirator
  • Climax 756 — half-face respirator with speaking diaphragm
  • Climax 810 — full-face respirator
  • ⚠️ Uses a non-standard thread — NOT compatible with 3M, Uvex, or other brand respirators

Climax 755 vs 3M 6051 — Which to Choose?

Feature 3M 6051 (A1 only) Climax 755 A1P2 ✓
Gas Protection A1 ✓ A1 ✓
Particulate Protection — (gas only) P2 NR ✓
Replaceable P2 Layer N/A ✓ (retainer ring)
Compatible With 3M bayonet masks Climax 755/756/810
Price 380 EGP 195 EGP ✓

Service Life & Replacement

  • P2 NR particulate layer: replace when breathing resistance noticeably increases, or at end of work shift — it is non-reusable (NR)
  • A1 gas filter body: replace when organic vapour smell is detected through the filter, or after 6 months from opening (whichever comes first)
  • Store in sealed bag away from direct sunlight, heat, and humidity when not in use
  • Always check expiry date printed on packaging before use

Full Specifications

  • Brand: Climax (Productos Climax, Spain)
  • Model: 755 A1P2 NR
  • Filter Type: Combined gas + particulate
  • Gas Class: A1 — organic vapours/gases, boiling point >65°C
  • Particulate Class: P2 NR (non-reusable)
  • Colour Code: Brown (A1) + White (P2)
  • Connection: Non-standard screw thread (Climax 755/756/810 only)
  • Body Material: Black ABS plastic
  • Certification: CE 0161
  • Standard: EN 14387:2004 + A1:2008
  • Pack: Sold as a pair (2 filters)
  • SKU: Filter-Climax-755-A1P2-NR

⚠️ Important: Non-standard thread — only fits Climax masks 755, 756, and 810. Not compatible with 3M or other brands. Do not use in oxygen-deficient atmospheres (<19.5% O₂). Replace P2 layer when breathing resistance increases. Replace gas filter when vapour odour is detected.


فلتر Climax 755 A1P2 NR مركّب – غاز وجسيمات

فلتر مركّب من الشركة الإسبانية Productos Climax، يجمع في قطعة واحدة حماية A1 ضد الأبخرة العضوية وحماية P2 NR ضد الجسيمات والرذاذ. الطبقة الجسيمية P2 قابلة للاستبدال بشكل منفصل عبر حلقة المثبّت، مما يُطيل عمر جسم الفلتر الغازي.

المميزات الرئيسية

  • حماية مزدوجة A1 + P2 NR — فلتر واحد يوفر حماية من الأبخرة العضوية والجسيمات في آنٍ واحد
  • طبقة P2 قابلة للاستبدال — تُثبَّت بحلقة مثبّت فوق غطاء الفلتر الغازي وتُستبدل عند انتهاء عمرها دون التخلص من جسم الفلتر الغازي
  • وسيط فلترة P2 متعدد الطبقات — مصمم لأقصى كفاءة تصفية للجسيمات الصلبة والسائلة
  • خيط تثبيت غير قياسي — متوافق حصراً مع أقنعة Climax موديل 755 و756 و810
  • يُباع بالزوج (فلتران في العبوة)

يحمي من

  • A1 — الأبخرة والغازات العضوية ذات نقطة غليان أعلى من 65°م (المذيبات، الهيدروكربونات، مرققات الدهانات)
  • P2 NR — الجسيمات الصلبة والسائلة، الأغبرة، الرذاذ، الأدخنة
  • رذاذ رش الدهانات وأبخرة المذيبات
  • رذاذ المبيدات الحشرية ذات المحتوى العضوي

الأقنعة المتوافقة

  • Climax 755 — قناع نصف الوجه من المطاط الحراري
  • Climax 756 — قناع نصف الوجه مع حاجب الكلام
  • Climax 810 — قناع كامل الوجه
  • ⚠️ خيط غير قياسي — غير متوافق مع أقنعة 3M أو Uvex أو أي ماركات أخرى

العمر الافتراضي والاستبدال

  • طبقة P2 NR: استبدلها عند زيادة مقاومة التنفس أو نهاية الوردية — غير قابلة لإعادة الاستخدام
  • جسم الفلتر الغازي A1: استبدله عند الشعور برائحة الأبخرة العضوية أو بعد 6 أشهر من الفتح
  • خزّن في كيس مغلق بعيداً عن الشمس والحرارة والرطوبة عند عدم الاستخدام

⚠️ تحذير: خيط غير قياسي — يناسب فقط أقنعة Climax 755 و756 و810. غير متوافق مع 3M أو غيرها. لا تستخدم في البيئات الفقيرة بالأكسجين (أقل من 19.5%). استبدل طبقة P2 عند زيادة مقاومة التنفس.

SKU: Filter-Climax-755-A1P2-NR | الماركة: Climax (إسبانيا) | الفئة: فلاتر أجهزة التنفس | المعيار: EN 14387:2004 + A1:2008 | CE 0161

Shipping cost is calculated based on weight and location. Simply add the products to your cart and use the Shipping Calculator to get the exact shipping fee